Skip to content

Platform Remote Sync

Introduction

The Remote Data Synchronization feature enables two distinct deployments of the West Connectivity to exchange data securely and efficiently through the Connectivity Hub service. The communication between two Connectors is a Source and a target configured in two West Connectivity deployments through a pairing process.

Paring Process

For source Connector, To enable Remote Data Synchronization, firstly you need to go to “remote-sync” tab of the “setting” page on Connector, and then enable the Enable Pairing to start the pairing countdown.

Remote Sync Setting

The pairing process needs to be finished before the countdown. If the process is expired, you need to enable the Enable Pairing again. And once the pairing is finished, you can’t disable the pairing or delete the Connector.

Once the pairing process is enabled, go to target portal console to create a target Connector with remote setting enabled. Enter all information from the source, including remote site identity, remote connector identity, to finish the pairing process.

Create Connector

Once the remote connector is created, it should be listed with a target icon.

Device List

Information Lookup

From the source Connector, user can real-time lookup device list or device state information from device page.

Target Device Page

Target Device state

the device setting is read only for target Connector. We don’t allow users on target Connector to be able to change settings or create a new device.

Enable Resource Data Synchronize

To start resource data synchronization, go to the source Connector resource setting page for setup. Enable the replicate setting to start the data synchronization. Then create the same resource on the target Connector to start receiving data.

Create New Resource

Limitation

The source Connector allows to be pairing with one target Connector only.

The data synchronization resuming is up to 7 days, Once the connection breaks for a while then reconnect back, the data may be lost if the data is generated over 7 days ago.